Resultado da pesquisa (3)

Termo utilizado na pesquisa Miranda S.

#1 - Protocols for preparation of platelet rich plasma (PRP) in Quarter Horses

Abstract in English:

This study compared two protocols for preparation of platelet rich plasma (PRP) and evaluated the association between manual and automated methods for platelet count using a prospective study design. Eight clinically healthy Quarter Horses had venous blood samples collected at rest. After collection, blood samples were centrifuged twice, using two different protocols including a period of sample resting, either at the start or at the end of the protocol. Platelet counting at the start of the protocol, during, and after obtaining PRP was conducted manually or with an automated counter, followed by comparison of the two methods. In order to investigate platelet degranulation during the protocol, vascular endothelial growth factor (VEGF) was measured at each preparation stage. The protocol with sample resting before centrifugation yielded a more concentrated PRP, and the study verified that both manual and automated methods are comparable and can be used interchangeably for platelet counting. VEGF concentration did not differ significantly between protocols, or among protocol stages. The results indicate that choice of protocol for PRP preparation will affect the quantity of platelets in the final product, although platelet degranulation was not observed as evidenced by the stable VEGF concentrations measured. A larger yield of non-degranulated platelets in PRP is desirable since more α-granules will be present, therefore Protocol II is recommended. Both manual and automated counts reliably allow clinicians to obtain platelet counts and the choice of utilizing a manual or automated method is unlikely to interfere with evaluation of the final PRP product.

Abstract in Portuguese:

Este estudo comparou dois protocolos de preparo de plasma rico em plaquetas (PRP) e avaliou a associação entre dois métodos de contagem plaquetária – um manual e o outro automático através de um estudo prospectivo. Sangue venoso de oito equinos da raça Quarto de Milha foi coletado e em seguida foi centrifugado duas vezes utilizando-se dois protocolos distintos: um com descanso antes da primeira centrifugação e outro após a segunda centrifugação. A contagem plaquetária ao início, no meio e ao final dos protocolos foi realizada manualmente e pelo método automatizado, seguida de comparação entre os dois métodos. Para investigar a degranulação plaquetária ocorrida durante o preparo do PRP, o fator de crescimento vascular endotelial (VEGF) foi mensurado em cada estágio dos protocolos. O método utilizando o descanso da amostra antes da primeira centrifugação proporcionou a obtenção de um PRP mais concentrado, além de o estudo verificar que ambos os métodos de contagem plaquetária (manual e automatizado) são comparáveis e podem ser usados indiferentemente. A concentração de VEGF não foi significativamente diferente entre os estágios de preparo do PRP. Os resultados indicam que o método de preparo afeta a quantidade de plaquetas obtidas no PRP, apesar da degranulação plaquetária não ter sido observada, como evidenciado pela concentração estável de VEGF. Uma maior concentração de plaquetas no PRP é desejável, pois indica que um maior número de α-grânulos estará presente na amostra, portanto, conclui-se que o Protocolo II é mais recomendável. Tanto o método manual, quanto o automatizado, pode ser usado de maneira confiável para a contagem plaquetária, não interferindo com a avaliação do produto final (PRP).


#2 - Renal artery Triplex Doppler and the relationship between kidney ecobiometry with atlanto-coccyges distance (ACD) and height (H) in Canis familiaris, 29(10):809-815

Abstract in English:

RESUMO.- Santana E. Jr M., Beserra P.S., Brito A.B., Miranda S.A., Nikolak E. & Domingues S.F.S. 2009. [Renal artery Triplex Doppler and the relationship between kidney ecobiometry with atlanto-coccyges distance (ACD) and height (H) in Canis familiaris.] Triplex Doppler da artéria renal e a relação entre a ecobiometria dos rins com distância atlanto-coccígea (DAC) e altura (H) em Canis familiaris. Pesquisa Veterinária Brasileira 29(10):809-815. Laboratório de Biologia e Medicina de Animais da Amazônia, Medicina Veterinária, Universidade Federal do Pará, Rua Hernane Lameira 556, Castanhal, PA 68743-050, Brazil. E-mail: shfarha@ufpa.br O objetivo do trabalho foi estabelecer a relação entre a ecobiometria renal com medidas de conformação corporal como a distância atlanto-coccígea (DAC) e a altura (H) de cães adultos saudáveis, obtendo-se parâmetros de normalidade para avaliar o tamanho e volume renal, bem como estabelecer valores de referência para avaliar a perfusão sanguínea dos rins por meio do índice de resistividade (IR) e do índice de pulsatilidade (IP) do ramo principal da artéria renal. No estudo foram utilizados 22 cães adultos sem raça definida, sendo 11 machos e 11 fêmeas. Os animais foram previamente aferidos quanto a DAC e a H. Os exames ultra-sonográficos foram realizados com um aparelho HDI 4000 PHILIPS munido de um transdutor microconvexo multifreqüêncial (5-8 MHz), dispositivos Doppler Colorido e Doppler de Fluxo. Os animais foram posicionados em decúbito lateral direito ou esquerdo, de acordo com o rim a ser avaliado. Os diâmetros longitudinal (DL) e dorsoventral (DDV) dos rins foram mensurados na secção longitudinal e, o diâmetro transversal (DT) foi aferido no plano transversal. O volume (V) foi calculado automaticamente pelo software do ultra-som. Com o uso do Triplex Doppler, o IR e o IP das artérias renais direita e esquerda foram obtidos. Todos os dados foram apresentados em média ± EPM. Análises de regressão linear foram realizadas tendo o DL, DDV, DT e V como variáveis dependentes e a DAC e H como variáveis independentes. Os IR e IP dos rins direito e esquerdo foram comparados pelo teste t de Student. A DAC variou de 54-78cm para machos e 37-71cm para fêmeas e a altura variou entre 34-64 cm para os machos e 24-57cm para as fêmeas. As médias obtidas para DL, DDV, DT e V dos rins esquerdo e direito foram: 5,24±0,27cm, 3,07±0,15cm, 3,07±0,9cm, 28,01±3,4mL e 4,50±0,19cm, 2,88±0,14cm, 2,71±0,15cm, 21,27±2,6mL, respectivamente. As análises de regressão linear entre as medidas lineares e volume renal com a DAC e a H foram significativas para os interceptos e coeficientes de regressão (P<0,01). Houve diferenças estatísticas quando comparado os IR e IP entre os rins direito e esquerdo (P=0,001), sendo que as médias para IR e IP dos rins esquerdo e direito foram 0,62±0,08; 1,34±0,18 e 0,70±0,06; 1,62±0,13; respectivamente. Os dados obtidos no presente trabalho podem auxiliar na avaliação do tamanho, volume e perfusão dos rins de cães adultos.

Abstract in Portuguese:

ABSTRACT.- Santana E. Jr M., Beserra P.S., Brito A.B., Miranda S.A., Nikolak E. & Domingues S.F.S. 2009. [Renal artery Triplex Doppler and the relationship between kidney ecobiometry with atlanto-coccyges distance (ACD) and height (H) in Canis familiaris.] Triplex Doppler da artéria renal e a relação entre a ecobiometria dos rins com distância atlanto-coccígea (DAC) e altura (H) em Canis familiaris. Pesquisa Veterinária Brasileira 29(10):809-815. Laboratório de Biologia e Medicina de Animais da Amazônia, Medicina Veterinária, Universidade Federal do Pará, Rua Hernane Lameira 556, Castanhal, PA 68743-050, Brazil. E-mail: shfarha@ufpa.br The aim of this paper was to establish the relation between the kidney ecobiometry with atlanto-coccyges distance (ACD) and height (H) in adult healthy dogs, to obtain normality parameters for assessment of renal size and volume, as well as establish reference values to evaluate kidney blood perfusion by the resistivity index (RI) and pulsatility index (PI) of main renal artery. The study was applied at 22 adult dogs, 11 males and 11 females. Previously, the DAC and H of all animals were measured. For ultrasonographic examination, the ultra-sound system HDI 4000 PHILIPS equipped with a multi-frequency microconvex transducer, Color Doppler and Spectral Doppler devices was used. The animals were placed into right or left lateral decubitus position, in agreement with the kidney to be assessed. The longitudinal (LD) and dorsoventral diameters (DVD) of kidney were measured in longitudinal plane, and the transverse diameter (TD) was determined in transversal section. The renal volume (V) was automatically calculated by the ultrasound software. With Triplex Doppler, the RI and PI of right and left main renal arteries were obtained. All data were represented in mean ± SEM. Linear regression analyses were performed with renal LD, DVD, TD and V as dependent variable, and ACD and H as independent variable. RI and PI were compared between right and left renal arteries with Student’s t-test. The LD, DVD, TD (cm) and V (ml) mean measurements for the left and right kidneys were: 5.24±0.27, 3.07±0.15, 3.07±0.9, 28.01±3.4 and 4.50±0.19, 2.88±0.14, 2.71±0.15, 21.27±2.6. All regression analyses were significant for the intercept and regression coefficient (P<0.01). There were statistical differences on RI and PI means between right and left renal arteries (P=0.001). The RI and PI means of left and right renal artery obtained were: 0.62±0.08 and 1.34±0.18; 0.70±0.06 and 1.62±0.13. The data obtained in the present paper can be used as parameters for evaluation of the renal size, volume and perfusion in adult dogs.


#3 - Relação entre a biometria ultra-sonográfica em modo B do globo ocular e os diâmetros fronto occiptal e bizigomático em Canis familiaris, p.286-290

Abstract in English:

ABSTRACT.- Beserra P.S., Sales G.A., Santana E.J.M., Miranda S.A., Brito A.B., Nickolak E., Freitas V.V. & Domingues S.F.S. 2009. [B-Mode Ultrasound biometry of the ocular globe related with fronto-occiptal and bizigomatic diameters in Canis familiaris.] Relação entre a biometria ultra-sonográfica em modo B do globo ocular e os diâmetros fronto occiptal e bizigomático em Canis familiaris. Pesquisa Veterinária Brasileira 29(4):286-290. Laboratório de Biologia e Medicina de Animais da Amazônia, Medicina Veterinária, Universidade Federal do Pará, Rua Hernane Lameira n° 556, Castanhal, PA 68743-050, Brazil. E-mail: shfarha@ufpa.br In the experiment 31 healthy mongrel dogs, 8 months to 7 years of age, were used, 10 males and 21 females, weighing 1.5-28 kg. Initially, fronto-occipetal (FOD) and bizigomatic (BZD) diameters were measured using a caliper. The ophthalmologic transpalpebral B-mode ultrasonography (US) was performed to measure the internal ocular structures, as follows: The cornea thickness (D1), distance between cornea and anterior lens capsule (D2), distance between cornea and posterior lens capsule (D3), lens thickness (D4), lens diameter (D5), lens area (D6), distance between posterior lens capsule and retina (D7), distance between anterior lens capsule and retina (D8), and the distance between cornea and retina (D9). Except for D4, there were effect of FOD and BZD on the measures of the internal structures of GO. The Lineal Regression Analysis between the measures of the internal oculars structures and DFO and DBZ were significant for D1, D2, D3, D4, D5, D6, D7, D8 and D9.

Abstract in Portuguese:

ABSTRACT.- Beserra P.S., Sales G.A., Santana E.J.M., Miranda S.A., Brito A.B., Nickolak E., Freitas V.V. & Domingues S.F.S. 2009. [B-Mode Ultrasound biometry of the ocular globe related with fronto-occiptal and bizigomatic diameters in Canis familiaris.] Relação entre a biometria ultra-sonográfica em modo B do globo ocular e os diâmetros fronto occiptal e bizigomático em Canis familiaris. Pesquisa Veterinária Brasileira 29(4):286-290. Laboratório de Biologia e Medicina de Animais da Amazônia, Medicina Veterinária, Universidade Federal do Pará, Rua Hernane Lameira n° 556, Castanhal, PA 68743-050, Brazil. E-mail: shfarha@ufpa.br In the experiment 31 healthy mongrel dogs, 8 months to 7 years of age, were used, 10 males and 21 females, weighing 1.5-28 kg. Initially, fronto-occipetal (FOD) and bizigomatic (BZD) diameters were measured using a caliper. The ophthalmologic transpalpebral B-mode ultrasonography (US) was performed to measure the internal ocular structures, as follows: The cornea thickness (D1), distance between cornea and anterior lens capsule (D2), distance between cornea and posterior lens capsule (D3), lens thickness (D4), lens diameter (D5), lens area (D6), distance between posterior lens capsule and retina (D7), distance between anterior lens capsule and retina (D8), and the distance between cornea and retina (D9). Except for D4, there were effect of FOD and BZD on the measures of the internal structures of GO. The Lineal Regression Analysis between the measures of the internal oculars structures and DFO and DBZ were significant for D1, D2, D3, D4, D5, D6, D7, D8 and D9.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV